BioProtect Balloon Spacer

Whole-gland spacing for modern prostate cancer radiation therapies.

BioProtect Balloon Spacer

Powering Treatment Forward

Diagram of BioProtect balloon spacer 17ml inflation volume

Predictable Spacing for Radiation Planning

BioProtect, the first non-gel spacer for prostate cancer radiation therapies, is made of biodegradable material and designed for control and reproducibility for treatment planning. BioProtect has been shown to provide consistent prostate-to-rectum separation across the entire prostate gland.1,2

Proven to Perform. Ready for SBRT.

BioProtect’s pre-formed shape creates consistent, stable, and symmetric spacing. Clinical studies demonstrate significant rectal dose reduction and support the use of BioProtect in advanced radiation treatment planning regimens, including moderate hypofractionation and SBRT.1,2

Features

Coverage at the Prostate Apex

BioProtect has been shown to consistently create measurable apical spacing, while gel spacers may not always do so.3 SBRT data demonstrate the importance of full-gland spacing, with ≥ 14 mm separation from base to apex yielding the lowest rectal dose.4

Visible, Stable Spacing

BioProtect is placed under TRUS guidance and is visible under CT, ultrasound, and MRI imaging.5 After placement, space created with BioProtect has been shown to be maintained through the course of treatment.1

Quality of Life Preservation

BioProtect achieved consistent spacing with significant rectal dose reduction in the pivotal trial.1 Follow-up showed sustained and statistically significant patient quality-of-life benefits in the bowel, urinary, and sexual domains.6*

14 mm mean apical separation Visible on CT, ultrasound, and MRI Bowel, urinary, and sexual benefits

* Preliminary data are from a conference abstract; not yet peer-reviewed; values and follow-up may change upon publication.

Designed for Modern Therapies

BioProtect fits within modern, efficient radiation therapy workflows.

Protection for Shorter-Course Regimens

Meaningful Dose Reduction

BioProtect’s significant rectal dose reduction across multiple modern radiation therapy regimens has been demonstrated in clinical and dosimetric planning studies.1,2

Prepared for Modern Planning

Supports Higher-Dose Regimens

Advancements in prostate radiotherapy demand consistent and reproducible anatomy. BioProtect provides dependable base-to-apex separation aligned to modern prostate radiation planning needs.1,2

Prioritizes 
Patient Quality of Life

Bowel, Urinary, and Sexual Benefits

BioProtect patients reported better maintenance of bowel, urinary, and sexual quality-of-life domains compared with control over 48 months6* — and BioProtect is the only spacer to show statistically significant preservation of sexual function.

* Preliminary data are from a conference abstract; not yet peer-reviewed; values and follow-up may change upon publication.

The BioProtect Difference: Dosimetric and Geometric Performance

Designed for consistent, full-gland spacing — including at the apex — BioProtect provides reproducible geometric separation that supports favorable dosimetry. Gel-based spacers can underperform inferiorly, where asymmetric or limited expansion may leave the apex of the gland insufficiently protected.3

BioProtect Balloon Spacer Gel Spacer
Performance

Prostate-rectum spacing (mean)

19 ± 3.7 mm1

12.6 ± 3.9 mm7

Separation symmetry

Consistent geometry1,3

Variable geometry3

Apical spacing

Consistent; base-to-apex symmetry1,3

Less consistent; variable inferior coverage3

Superior Dose Reduction

VMAT, conventional fractionation plan rectal V70 dose2

84.1% 67%

SBRT, ultra hypofractionated plan rectal V31.7 dose reduction2

84.1% 68.1%

Explore the Apex of Spacing

Learn more about the clinical evidence supporting the BioProtect Balloon Spacer, the BioProtect procedure, and meet the BioProtect team.